FC600 Operating Specifications

  • Operating fluid pressure range: 0 to 35 kPa ( 0 to 5 psig) @ 80°C (176°F)
  • Operating fluid temperature range: 1 to 80°C (33 to 176°F)
  • Maximum Pressure differential on tubing: 35 kPa (0 to 5 psid) @ 80°C (176°F)
  • Negative pressure differential will collapse tubing and must be avoided
  • Storage temperature range: -30 to 60°C (-22 to 140°F)

FC600 Materials of construction

  • Housing / Shell – Machined Polypropylene
  • End caps – Machined Polypropylene
  • Seals – EPDM (peroxide cured)
  • Tube bundle headers – Thermoset polyurethane
  • Membrane tubing – Nafion™ polymer

IMPORTANT – WARNING! Due to differing rates of expansion, metal fittings are not recommended. ABS or Nylon fittings are required. Additionally, DO NOT USE teflon tape when attaching fittings to Perma Pure humidifiers. Using either metal fittings or teflon tape will cause the end caps to crack, leading to leaks (and voiding the warranty).

FC600

Dimensions

Model Number A B
Nom.
C D Flow Rate (slpm)
Gas-to-Gas Water-to-Gas
Approach Temp.* Flow vs Dewpoint
4 deg
6 deg 9 deg
FC600-7000-7PP 14.75″ 7″ 5.75″ 1.5″ N/A
FC600-7000-8PP 15.75″ 8″ 6.75″ 2.5″ 583 1400 1860
FC600-7000-10PP 17.75″ 10″ 8.75″ 4.5″ N/A
FC600-7000-14PP 21.75″ 14″ 12.75″ 8.5″ 1020 2450 3267
FC600-7000-15PP 22.75″ 15″ 13.75″ 9.5″
FC600-7000-16PP 23.75″ 16″ 14.75″ 10.5″

* The performance information for the gas-to-gas units are expressed as the flow rate of air (slpm) in relation to the approach dew point temperature. The approach temperature is defined as the difference between the cathode exhaust stream entering the humidifier and the humidifier exhaust stream going to the stack. For example, if the cathode exhaust dew point entering the humidifier is 67° and the humidifier generates a dew point of 61°, it would have been sized for a 6° approach temperature.